品牌 | SKC/美国 |
---|
Deployable Cartridge Sampler (DCS) System
The SKC Deployable Cartidge Sampler (DCS) System offers cost-effective ambient air sampling of PAHs, PCBs, pesticides, and associate particulates. With its fully programmable Li-Ion powered Leland Legacy Sample Pump and specially designed sampling head that holds a media cartridge, the DCS is ideal for fenceline monitoring, near-roadway monitoring, saturation sampling, and eight-hour remediation monitoring.
Deployable Cartridge Sampler (DCS) System
Deployable Cartridge Sampler (DCS) System
Performance Profile
See Reference below for DCS performance testing.
Flow Rate | 10 L/min |
Run Time | > 24 hrs (one battery charge) |
Power | Rechargeable Li-Ion battery, 7.4 V, 12-Ah capacity, 88.8 Wh |
Case Dimensions | 18.5 x 14.1 x 6.9 in (47 x 36 x 18 cm) |
System Weight | 12.2 lbs (5.5 kg) |
Reference
Patterson, S. L., Rusiecki, J. A., Barnes, S. L., Heller, J. M., Sutphin, J. B., Kluchinsky Jr., T. A., “Effectiveness, Suitability, and Performance Testing of the SKC Deployable Particulate Sampler (DPS) as Compared to the Currently Deployed Airmetrics MiniVol Portable Air Sampler," Journal of Environmental Health, Vol. 73, No. 3, pp. 16 to 22