当前位置:首页  >  产品展示  >  空气采样设备  >  PM2.5大气颗粒物监测仪  >  225-392冲击式采样器IMPACT Sampler

冲击式采样器IMPACT Sampler

【概要描述】冲击式采样器IMPACT Sampler影响采样单级惯性冲击器,样品的PM10,可入肺颗粒物,或PM(10-2.5)在10升/分钟。高流量提高了采样灵敏度使其成为理想的环境取样和室内空气的研究。影响的可拆卸过滤盒和一次性前油冲击盘使其快速和易于部署(不清洁或润滑)。影响是在SKC展开微粒采样器的采样头(DPS)系统。该建议使用冲击利兰的遗产采样泵。

型号:225-392 点击量:1812 厂商性质:代理商 更新日期:2024-09-23
产品详情
品牌SKC/美国

冲击式采样器IMPACT Sampler

环境空气取样和室内空气研究的理想选择
在10升/分钟情况下,可使用任何泵
紧凑型设计
更高的流量提供了更高的灵敏度
操作方便
快速媒体变化的可移动过滤盒
一次性准备使用前油冲击盘减少颗粒反弹不清洁或润滑
包括雨盖保护取样在室外使用
可选的快速安装支架固定采样器几乎任何地方

冲击式采样器IMPACT Sampler

采集PM10,PM2.5,或PM粗(10-2.5um)在10升/分钟。高流量提高了采样灵敏度使其成为理想的环境取样和室内空气的研究。影响的可拆卸过滤盒和一次性前油冲击盘使其快速和易于部署(不清洁或润滑)。影响是在SKC展开微粒采样器的采样头(DPS)系统。该建议使用IMPACT冲击样泵。

Performance Profile

Flow Rate

10 L/min

50% Cut-point

2.5 μm or 10 μm (model dependent)

Impaction Discs

Recommended impaction disc to reduce particle bounce: 37-mm disposable pre-oiled porous plastic disc 

For chemical analysis of larger particles: 37-mm filter (quartz or PTFE) 
Back pressure on PTFE filters can vary within the same lot.

Collection Filter

47-mm filter (requires impaction substrate), select material based on application

Impactor Material

Aluminum (inlet) with brass barbed fitting for 3/8-in ID tubing

Dimensions

2.6 dia. X 1.8 H x 3.8 L in (7 x 5 x 10 cm)

Weight

0.5 lb (0.23 kg)


Cat. No.Description+
225-394
Calibration Adapter, for IMPACT Sampler
Calibration Adapter, replacement, for use with IMPACT Sampler, also used with DPS System, ea
225-397Filter Holder Opener, IMPACT SamplerFilter Holder Opener, IMPACT Sampler
Filter Holder Opener, replacement, for IMPACT Sampler, also used with DPS System, 1 ea
225-396Filter Holder, IMPACT SamplerFilter Holder, IMPACT Sampler
Filter Holder, replacement, for IMPACT Sampler, holds 47-mm collection filter, also used with DPS System, ea
770-805
HAZ-SCANNER Nitrogen Dioxide Sensor
Nitrogen dioxide sensor, for HAZ-SCANNER
Measures 0 to 50 ppm
EDC No. EDC GB ND-2000
225-3911
IMPACT Sampler, for PM Coarse Sampling at 10 L/min
IMPACT Sampler, two-stage inertial impactor for 10 L/min ambient PM Coarse (PM10-2.5) sampling, includes filter cassette (holders), calibration adapter, rain cap and PM Coarse Ring (Cat. No. 225-3912); suitable for use with sampling pumps operating at 10 L/min
225-390
IMPACT Sampler, for PM10 Sampling at 10 L/min
IMPACT Sampler, single-stage inertial impactor (included in DPS System) for 10 L/min ambient PM10 eampling, includes filter cassette, calibration adapter, and rain cap; suitable for use with sampling pumps operating at 10 L/min
225-392
IMPACT Sampler, for PM2.5 Sampling at 10 L/min
IMPACT Sampler, single-stage inertial impactor (included in DPS System) for 10 L/min ambient PM2.5 Sampling, includes filter cassette (holder), calibration adapter, and rain cap; suitable for use with sampling pumps operating at 10 L/min
225-395Impaction Substrates, 37 mm, for IMPACT SamplerImpaction Substrates, 37 mm, for IMPACT Sampler
Impaction Substrates, replacement, 37-mm porous plastic support pads, pre-oiled, ready to use, disposable, for use with IMPACT Sampler, also used with DPS System, pk/25
225-395AImpaction Substrates, 37 mm, for IMPACT SamplerImpaction Substrates, 37 mm, for IMPACT Sampler
Impaction Substrates, replacement, 37-mm porous plastic support pads, pre-oiled, ready to use, disposable, for use with IMPACT Sampler, also used with DPS System, pk/50
225-395BImpaction Substrates, 37 mm, for IMPACT SamplerImpaction Substrates, 37 mm, for IMPACT Sampler
Impaction Substrates, replacement, 37-mm porous plastic support pads, pre-oiled, ready to use, disposable, for use with IMPACT Sampler, also used with DPS System, pk/10
225-399Mounting Bracket, for IMPACT SamplerMounting Bracket, for IMPACT Sampler
Mounting Bracket Replacement, for IMPACT Sampler, also used with DPS System, ea
225-3912PM Coarse Ring, for IMPACT PM10 SamplerPM Coarse Ring, for IMPACT PM10 Sampler
PM Coarse Ring, for use with IMPACT PM10 Sampler, adapts IMPACT PM10 Sampler to an IMPACT Coarse, includes filter cassettes
225-398Rain Cap, IMPACT SamplerRain Cap, IMPACT Sampler
Rain Cap Replacement, for IMPACT Sampler, also used with DPS System, ea
P31988Replacement Impactor Exhaust O-Ring, for the IMPACT Sampler and DPS SystemReplacement Impactor Exhaust O-Ring, for the IMPACT Sampler and DPS System
Replacement Impactor Exhaust O-Ring, for the IMPACT Sampler and DPS System, ea
P31989Replacement Impactor Inlet O-Rings, for the IMPACT Sampler and DPS SystemReplacement Impactor Inlet O-Rings, for the IMPACT Sampler and DPS System
Replacement Impactor Inlet O-Rings, for the IMPACT Sampler and DPS System, pk/3
P54202Replacement Impactor Inlet, 10 μm, for IMPACT SamplerReplacement Impactor Inlet, 10 μm, for IMPACT Sampler
Replacement Impactor Inlet, 10 μm, for IMPACT Sampler, ea
P54204Replacement Impactor Inlet, for IMPACT Sampler and DPS SystemReplacement Impactor Inlet, for IMPACT Sampler and DPS System
Replacement Impactor Inlet, 2.5 μm, for IMPACT Sampler and DPS System, ea

联系方式

邮箱:[email protected] 地址:上海市嘉定区槎溪路222弄10号楼531室
咨询热线

016-27058191

(周一至周日9:00-19:00) 在线咨询
1688网站
微信二维码
上海会彬仪器有限公司©2024版权所有    备案号:豫ICP备27058191号 技术支持:        sitemap.xml